Load Cells  "  SL-A

 

 

Application:  Applicable to Hopper Scale, Belt Scale and is ideal for the conversion of existing mechanical scales.
 
 


 

Rated Load

Dimensions in ‘mm’

A

B

C

M

2, 5 kg

70

10

60

M6

10 kg

50.8

12.7

63.5

M8

20, 30kg

50.8

19.05

76.2

M10x1

50 kg ~ 500 kg

50.8

19.05

76.2

M12x1.75

 
 
 Technical Data:
 

Capacities

2, 5, 10, 20, 50, 100, 200, 300, 500 kg

Output Sensitivity

2.0 ± 10% mV/V

Non - Linearity 

± 0.03% FS

Repeatability

± 0.02% FS

Hysteresis 

± 0.03% FS

Creep (20 min)

± 0.03% FS

Zero Balance

± 1% FS

Insulation Resistance

> 5000 MΩ (@ 50V DC)


Resistance

 

Input

Output

400 ± 10Ω

350 ± 3Ω


Temperature Range

 

Compensated

Operating

-10 ~ +50°C

-30 ~ +60 °C


Temperature Effect

 

Output

Zero

± 0.02% FS/10°C

± 0.03% FS/10°C

Maximum Excitation Voltage

12V (DC/AC)

Recommended Excitation Voltage

10V (DC/AC)

Safe Overload

120% FS

Maximum Overload

150% FS

Construction

Aluminium Alloy

Environmental protection

IP 65

Connecting Cable

Ø6 x 3.5m

 
 
 

QPL | TT-SS | TT | TTX-S | TTX-B | PF | PFS-310  | PFS-410  | PFS-810  | SL-A | SLSBB | SB | DESB | DESB-A | DESB-B | TCLC | RTLC | MCLC | MCLC-B | CMLC | ULC | CP | LPLC

 