Paddle Wheel Sensor And Flow Meters

 
 
FLOW METER FLOW SENSOR SENSOR INSTALLATION FITTINGS

 

 

HARIS flow measurement system, takes of all your flow measurement and monitoring system needs with maximum efficiency. the system comprises of a paddle wheel sensor, Digital flow meter and sensor installation fittings.

Principle of operation :

The most commonly employed measurement principle is to measure the liquid's velocity and the pipe area Flow rate = Velocity x Area.

The HARIS paddle wheel flow sensor, works on this simple but accurate principle. Four blades spin past a sensor in the housing body. As the fluid flow causes the rotor to rotate, a signal is produced proportional to the flow rate. The design of the rotor ensures a linear repeatable output upto a flow velocity of 7 m/sec with an accuracy of ± 0.06 m/s.

The signal is fed to the fully digital, user programmable Flow meter for a digital display of flow rate. & totalized flow. The PDLC 4080B can be used for batching applications. HARIS Flow meter allow field Calibration of sensor for achieving maximum accuracy. Advanced digital damping filter with users settable time factor ensure steady readings in pulsating flow conditions. In the event of power failure the non volatile memory retain its configuration and fertilizer data.

The RS 232 communication for PC interface is a standard feature in all HARIS Flow meter. Combined with a powerful data logging software this option provides a cost effective data logging solution. 

   
       Applications :       Features :
   
  • Reverse osmosis & water treatment.
  • Resource auditing system
  • Cooling water monitoring
  • Municipal water auditing
  • Distribution for commercial facilities.
  • Borewell water monitoring
  • HVAC
  • Linear & accurate
  • Cost effective
  • User programmable
  • Rate indicator, Totalizer & Batcher functions.
  • Computer interface - electronic data logging
  • Easy maintenance.
 
Specification:    
 

Accuracy

2 % of Full scale

Operating Range

0.3 - 6.0 m/s

Viscosity

1.0 Centipoise (water like)

Max. Pressure

10 bar

Max Solids

< 100 micron dia. & length

Standard Cable Length

3 m

Sensor Excitation

12 V DC

Display

16 Char Dot Matrix LCD

Keyboard

5 Keys sealed tactile

Units

Lps, Lpm , Lph

Totalizer Range

255 million 999999 Litres.

Calibration

Digitally Programmable

Supply Voltage

220 ~ 240 V AC; 50 Hz.

Output Ports

RS 232C

Digital Datalogger

Optional

Back view


 
 

Load Cells | Pressure Transducers /Transmitters | Digital Pressure Gauges | High Melt Pressure Transducers
 | Electro Magnetic Flow Meters | Paddle Wheel Sensor & Flow Meters

 