Digital Pressure Gauge
"
DPGST |
|
|
|
|
|
The digital
pressure gauge with 1.5 % full accuracy. This developed technology
delivers stable and long lasting performance. It has a 5 ½ digit
backlit LCD. It was built for the applications, which the cost for
digital solutions is highly concerned. The Digital pressure gauge is
rugged and features High Pressure Capture with pressure ranges ranging
from vacuum (bar, Hg, cmHg, mmHg) to 15,000 PSIG. It is also displayed
in bar, kg, kg/cm2, Mpa and kPa). It has an AC power
adaptor of 100 – 240 volts with 50 –60 Hz for installation. Also has
an optional power supply, DC 5 –24 volts.
This pressure gauge is used in applications in test and measurement in
the process industries, hydraulic and pneumatic systems,
Industrial gases, industrial machinery and machine tools, injection
moulding machines, stamping and forming presses and pumps
and compressors. It was built for the applications, which the cost for
digital solutions is highly concerned. |
|
|
|
|
FEATURES |
-
1.5% Full Scale Accuracy
-
Ranges from Vacuum to 15,000 psig
(1,000 kg/cm2)
-
Positive Pressures (bar, psi, kg/cm2, mpa and kpa)
-
Negative Pressures (hg, cmhg, mmhg,
bar)
-
5 ½ Digit Blue / Green Backlit LCD
-
High Pressure Capture
-
CE Compliant
-
Rugged ABS Plastic Housing with black lacquered.
-
Customer Recalibration
-
Zero Offset/ Tare
|
 |
 |
|
|
|
|
|
|
|
|
|
SPECIFICATIONS:- |
|
Pressure Range |
Negative
(vacuum) & Positive
(0 –15000 psi) |
|
Accuracy Standard
|
± 1.5 % Full
Scale |
|
Diameter |
3 inches (78
mm) |
|
Temperature
Range
Operating / Medium |
- 10°C - 100°C |
|
Storage |
+ 10° - + 50°C |
|
Ambient
|
+ 10° - + 75°C |
|
Burst Pressure
|
200 % full
scale |
|
Engineering
units |
Vacuum bar :
Hg, cmHg, mmHg
Positive bar: psi, kg/cm2, Mpa, kPa |
|
LCD Display |
5 ½ digit LCD,
Blue/Green Backlit – 0.5“ |
|
Connection
|
¼” Male NPT |
|
Power Input
|
220 – 240 V AC,
adaptor @ 50 Hz |
|
*Output
|
5 V DC @ 1000
mA |
|
Case material |
ABS |
|
Wetted parts
|
SS
|
|
Peak Hold
|
Standard
|
|
# Relay output |
1 standard,
Max. 8 set points (optional) |
|
|
*,# (in case of switch) |
|
|
|
|
|
Dimension (With
Flange) |
Dimension (With
Flange) |
|
 |
 |
 |
|
|
|
|
Model |
D |
D1 |
D2 |
B |
B1 |
B2 |
S |
S1 |
S2 |
S3 |
R |
G |
|
With Flange |
78 |
64 |
110 |
49 |
14 |
35 |
28 |
27 |
|
|
14 |
112 |
|
DPG / DPS |
78 |
64 |
|
49 |
14 |
35 |
32 |
23 |
|
|
14 |
112 |
|
With Lower Back Mount |
78 |
64 |
110 |
22 |
30 |
42 |
28 |
27 |
|
|
14 |
112 |
|
|
|
|
|
| |
|
PRESSURE GAUGE |
PRESSURE SWITCH |
|
Specifications: |
Pressure Ranges
PSI / Kg
|
Maximum Safe
Over Pressure
PSI / Kg.
|
Incremental
Display Steps
PSI / Kg
|
|
Pressure Ranges |
Negative (vacuum) & Positive
(0 –15000 psi) |
0 –15/1
|
19.5 /1.3
|
.10/0.01
|
0-30/2
|
39.0/2.6
|
.20/0.02
|
|
Accuracy |
±
1.5 % Full Scale |
0-40/3
|
52.0/3.9
|
.26/0.02
|
|
Diameter |
3 inches (78 mm) |
0 –60/4
|
78.0/5.2
|
.40/0.03
|
|
Temperature Range |
- 10°C
- 100°C |
(0 –100/7
|
130.0/9.1
|
.66/0.05
|
|
Storage |
+ 10°
- + 50°C |
0-140/ 10
|
182.0/13
|
.93/0.06
|
|
Ambient |
+ 10°
- + 75°C |
0-200/15
|
260.0/19.5
|
1.30/0.1
|
|
Burst Pressure |
200 % full scale |
0-280/20
|
364.0/26
|
1.86/0.2
|
|
Engineering units |
Vacuum bar : Hg, cmHg, mmHg
Positive bar: psi, kg/cm2, Mpa, kPa |
0-350/25
|
455.0/32.5
|
2.33/0.2
|
0-500/35
|
650.0/45.5
|
3.33/0.3
|
|
LCD Display |
5 ½ digit LCD,Blue/Green Backlit – 0.5“ |
0-570/40
|
741.0/52
|
3.80/0.3
|
|
Connection |
¼” NPT- M |
0-700/50
|
910.0/65
|
4.66/0.4
|
|
Power Input |
220 – 240 V AC, adaptor @ 50 Hz |
0 -1000 (1K)/70
|
1,300.0/91
|
6.66/0.5
|
|
*Output |
5 V DC @ 1000 mA |
0-1400 (1.4 K)/100
|
1820.0/130
|
9.33/0.7
|
|
Case material |
ABS |
0-2100 (2.1K)/150
|
2730.0/195
|
14.00/1
|
|
Wetted parts |
SS |
0 –2800 (2.8 K) /200
|
3,640.0/260
|
18.66/1.5
|
|
Peak Hold |
Standard |
0 –3500 (3.5 K) /250
|
4,550.0/325
|
23.33/1.5
|
|
# Relay output |
1 standard, Max. 8 set points (optional) |
0 – 4200 (4.2K)/300
|
5,460.0/390
|
28.00/2
|
|
|
|
0 –5000 (5K) / 350
|
6,500.0/455
|
33.33/2.5
|
|
|
|
0 – 5700 (5.7K)/400
|
7,410.0/520
|
38.00/2.5
|
|
|
|
0 – 7000 (7K)/500
|
9,100.0/650
|
46.66/3.5
|
|
|
|
0 – 8500 (8.5K)/600
|
11,050.0/780
|
56.66/4
|
|
|
|
0 – 10,000 (10K)/ 700
|
13,000.0/910
|
66.66/4.5
|
|
|
|
0 –15,000(15K)/1000
|
19,500.0/1300
|
94.66/6.5
|
Maximum safe over pressure is the pressure which the unit can
experience occasionally without loss of accuracy of permanent
damage.
|
|
|
|
|
|
|
|
|
|
|
|
LCD |
LED |
DPG-L |